· Updated · Jiří Škapa · Data Converters · 13 min read
ADC3669 SYSREF Monitor Reads 0x00: An Unlisted Register Bit and Where SYSREF Is Captured
The SYSREF monitor of the ADC3669 read 0x00 on our board until we set a bit that the data sheet does not list. What the monitor then shows, why it does not show the point where SYSREF is captured, and what else it took to get the same receive phase after every initialisation.

Our board has two ADC3669s, dual 16-bit converters from Texas Instruments, clocked at 500 MHz and used with their digital down-converters. An LMK04832 supplies their clock and SYSREF. The FPGA labels every received sample with a time stamp counted in 4 ns ticks from SYSREF. We wanted to check the SYSREF timing with the monitor built into the ADC, and to get, on each of the four channels, the same phase and the same time stamps after every initialisation: the sequence that programs the clock generator, configures the converters and ends with one common SYSREF pulse.
The clock goes from the generator straight to each ADC. SYSREF leaves the generator as LVDS and reaches the GPIO0 pin of the ADC through an LVDS line receiver with a CMOS output. The generator delays each SYSREF output separately.
The monitor read 0x00 whatever we did. What we found:
- The SYSREF monitor responds only while bit 7 of register 0x147 is set. The data sheet does not list this register. While the bit is set, the LVDS frame of the ADC no longer follows SYSREF.
- The monitor does not show where SYSREF is captured. The point where the capture moves to the next clock cycle lies about 0.6 ns before the clock edge that the monitor reports, not 60 ps after it as the data sheet says.
- The line receiver in the SYSREF path makes the SYSREF timing a property of the individual board. The software has to measure it.
- A clock divider in the FPGA is not aligned to SYSREF and adds an ambiguity of its own.
These are observations on the two devices of one board. The finding about register 0x147 is also posted on TI’s E2E forum, as a follow-up to our original question. As of 23 November 2026, Texas Instruments has not confirmed it.
The monitor reads 0x00
The monitor is described in section 8.3.3.1 of the data sheet (SBASAL3B, revised June 2025). Register 0x140 reports whether a SYSREF edge was detected (bit D6, SYSREF DET) and in which of five windows of 40 ps around the rising edge of the sampling clock it fell (flags X1 to X5; X2 is the window at the clock edge). A well-placed SYSREF reads 0x40: detected, and no edge within the 200 ps of the windows. A readout of 0x00 means that the monitor saw no SYSREF at all.
That is what both ADCs read, although SYSREF worked: it reset the NCOs, the LVDS frame aligned to it, and an oscilloscope showed clean logic levels at the pin. The SPI readout was sound as well: the registers at the neighbouring addresses read back what was written. None of the following changed the readout:
- the polarity of SYSREF,
- a single pulse, a pulse train or a continuous SYSREF, sent before, during and after the reset of the ADC,
- DDC mode or DDC bypass, and both GPIO configuration codes with SYSREF on GPIO0 and GPIO1 unused,
- the SYSREF triggered over SPI,
- the position of the edge, moved across more than one clock period in 102 steps, most of them 21 ps and none more than about 0.15 ns, less than the 200 ps of the windows.
Bit 7 of register 0x147
The register map of the data sheet goes from 0x146 straight to 0x14A. We tried the addresses that the map skips, one bit at a time: set the bit, clear SYSREF DET, send one SYSREF pulse, read 0x140, restore the register.
One bit made the difference: bit 7 of register 0x147. With it set, 0x140 reads 0x40 after every pulse on both ADCs, 0x00 after the flag is cleared, and 0x40 again after the next pulse. When the SYSREF edge is moved, the window flags appear in the order X1 to X5, as the figure in the next section shows.
There is a catch. While the bit is set, the LVDS frame no longer follows SYSREF: the pulses that the monitor sees do not synchronise the ADC. We checked the frame only, not the reset of the NCO. With the bit cleared the frame follows SYSREF again, without a reset. The monitor therefore needs a sequence of its own:
- Set 0x147 bit 7.
- Clear SYSREF DET: 0x102 bit 6 to 1 and back to 0. Setting bit 7 sets SYSREF DET by itself.
- Send one SYSREF pulse and read 0x140.
- Clear 0x147 bit 7.
- Only then send the SYSREF pulse that synchronises the ADC.
Writing to a register that the data sheet does not describe is at your own risk. Some of the unlisted registers hold values that differ from device to device and look like factory trims; restore what you change.
The monitor does not show where SYSREF is captured
What matters for the placement of SYSREF is the capture point: the SYSREF delay at which the ADC starts to capture SYSREF one clock cycle later. Two effects of SYSREF in DDC mode show it. The LVDS frame arrives one clock cycle later, and the word alignment in the FPGA reports a different position. The NCO is reset one cycle later, and the phase of a received CW tone steps.
We delayed SYSREF with the analogue delay of the generator, nominally 21 ps per step, sent one pulse per step and read the frame position and the phase of the tone after each. Then we repeated the sweep with bit 7 set and read the monitor.
Top: delay of the LVDS frame while SYSREF is delayed, with bit 7 cleared. The frame moves by one clock cycle, 2 ns, between 315 and 336 ps for ADC 1 and between 441 and 462 ps for ADC 2 (dashed lines). The phase of the received tone steps at the same delay setting. Bottom: the monitor flags with bit 7 set; grey dots are settings without a flag. The data are two sweeps of the fine delay, taken at two coarse settings of the generator 1 ns apart; both go on to 1483 ps without a change. The delay values are nominal.
The frame position and the NCO phase change at the same step on both ADCs. The monitor does not agree with them: it raises no flag at the capture points, and the frame does not move where the flags are. For ADC 2 the X2 window, which the data sheet puts at the clock edge, lies 0.64 ns after the capture point. For ADC 1 the X2 window falls just before the start of the sweep; inferred from its X3 to X5 flags, the distance is about 0.6 ns. Two coarse steps earlier the same flags appear at the same fine settings: two coarse steps are one clock period. The fine step is within about 10 % of its nominal 21 ps, which adds a few tens of picoseconds of uncertainty.
According to the data sheet the ADC itself uses the sample taken 60 ps after the clock edge, which puts the capture point between X3 and X4. We find it about 0.7 ns earlier. That fits neither the rising edge of the clock nor, at a duty cycle of 50 %, the falling edge 1 ns away. We cannot tell the cause. Bit 7 may select a test mode rather than enable the monitor: the monitor and the frame were never seen to respond to the same pulse. Or the ADC may capture SYSREF on another edge of an internal clock; the data sheet names the rising edge in section 8.3.3.1 and in the timing table, and the falling edge in the description of register 0x140. We did not measure SYSREF relative to the clock at the pins.
The monitor is useful for relative measurements: it shows with about 40 ps resolution whether the SYSREF edge moves relative to the clock, over time or from one board to the next. It does not tell you where to put the edge. For that, find the capture point from the frame position or the NCO phase and keep the edge away from it.
Measure the SYSREF timing on every board
The LVDS line receiver is in the SYSREF path only; the ADC clock does not pass through such a part. Its data sheet gives a typical propagation delay of about 3 ns and a maximum, but no minimum. With a clock period of 2 ns, the data sheets therefore do not fix where the SYSREF edge falls. It differs from part to part and must be expected to move with temperature and supply voltage; we have not measured that. The setting that aligns SYSREF and clock at the outputs of the generator can put the edge right at the capture point. The steps of the generator need checking as well: the half step of the LMK04832 SYSREF output came out noticeably shorter than its nominal value on our board.
The initialisation of the board therefore measures the timing:
- It steps the SYSREF delay through one period of the ADC clock, one pulse per step, and finds the capture point of each ADC from the frame position. The SYSREF outputs to the other destinations are held low meanwhile; one common pulse to all follows at the end.
- The default setting lies about midway between two capture points: on our board 0.8 to 0.9 ns after one and 1.1 to 1.2 ns before the next, for both ADCs. It is kept while it is at least about 350 ps away from the nearest capture point. The data sheet asks for 100 ps of setup and 100 ps of hold time; the rest is margin for the line receiver over temperature and supply.
- Otherwise it chooses another setting in the same clock cycle. It never crosses a capture point, because that changes the latency of the ADC by one clock cycle.
- It reports an error when no such setting leaves about 350 ps, or when the capture point is within about 150 ps of the default and its clock cycle cannot be determined.
This keeps the latency of one board constant. It does not make two boards equal: their line receivers can put them in different clock cycles. When the default is moved across a capture point, the latency of the ADC changes by one clock cycle; the frame position that the FPGA aligns to and the sample that gets a given time stamp move with it and have to be measured again.
The FPGA adds an ambiguity of its own
With SYSREF captured safely, the time stamps of the received samples can still move from one initialisation to the next. The dividers of the clock generator and of the converters are aligned by SYNC and SYSREF. A divider in a PLL of our FPGA has no such input: a clock divided by two comes up in one of two phases each time its PLL locks, and data timed by it comes out a cycle earlier or later. In our case the result is a step of 4 ns, one tick of the time stamp.
Avoid the divider where you can: let the generator supply the clock at the frequency at which the logic uses it. Where a divided clock remains, the software has to detect its phase after every lock and repeat the lock until it is the required one. Which phase is required depends on the clock cycle in which the ADC captures SYSREF.
Results
Two measurements check the result. In both, a DAC on the same clock generator sends a signal through a loopback on the board to all four inputs.
Phase and delay with a multitone signal. The DAC plays a periodic multitone signal, 319 tones across 39 MHz, restarted by SYSREF. After each initialisation, a line fitted to the phases of the tones gives the delay of each channel and its phase at the centre of the band. The receiver records a block that starts at a fixed time stamp, so a time stamp that is off by one tick would show as a 4 ns step of the delay. The external inputs were terminated.
Phase of the four channels after each of 640 initialisations, on a scale of ±5°: five power cycles, each idle for 20 minutes after power-on and then initialised 128 times in 12 minutes. Each power cycle is drawn relative to its median from 3 minutes on. The first initialisation starts the DAC; the phase then falls by about 2° and is within about 0.2° of its end value after 4 minutes (shaded). The fall is the same on all four channels and includes the transmit path.
The loop delay of every channel stayed within 7 ps peak to peak in each power cycle and within 1.2 ps from one power cycle to the next; one tick would be 4000 ps. Neither the transmit timing nor the receive time stamps stepped. After the warm-up, the phase of a channel has a standard deviation of 0.03° to 0.09° over the initialisations of one power cycle, most of it slow drift. The phase between two channels is steadier, because the drift is common to them: its standard deviation is 0.005° to 0.013°, and over the five power cycles its mean stayed within 0.035° and the delay between two channels within 1.3 ps. The phase common to all four channels differed by up to about 0.25° between the power cycles.
Time stamps with a reference tone. A loopback measures the sum of the transmit and the receive timing. To see the receive time stamps alone, the DAC generates a CW carrier with its own NCO, so the transmit data path is not involved, and the NCOs of the ADCs are tuned 9.765625 MHz away from it. All NCOs are reset by the same SYSREF pulse, so at a given time stamp the received tone has the same phase after every initialisation. A time stamp that is off by one tick moves the phase by 360° × 9.765625 MHz × 4 ns = 14.06°. No such step appeared in 450 initialisations, 200 of them spread over ten power cycles. In part of them an external signal on the inputs of ADC 1 moved their phase by up to 4.6°, still far from 14°.
In a run of 90 minutes at a temperature constant within 0.3 °C, the capture point of neither ADC moved by more than the resolution of the scan, about 20 ps for one ADC and about 60 ps for the other.
Not tested yet: temperature. The board was between 27.7 and 31.4 °C in all these measurements.
Written by
Jiří Škapa · Lead RF/FPGA engineer at JSE
Jiří has designed RF and signal-processing hardware and FPGA firmware since 2003, starting with receivers and signal-processing boards for radar systems. He holds a master's degree in radio engineering from the Czech Technical University in Prague.